Energy availability and use
What this room can still sell, what it draws right now, and what that costs. All figures update from live telemetry every 5 seconds.
Facility load, last 24 hours
IT load, cooling and electrical losses, in kW at 15-minute intervals.
Attention
Open findings across audit, billing and capacity.
Capacity by constraint
Dark bar is measured peak, light bar is contracted. The outlined constraint sets what you can sell.
Money on the table
Monthly value found by the console that is not yet captured.
Digital twin
Floor plan of SHR-01 from inventory, colored by live telemetry. Select a rack for its detail.
Power chain
Utility to rack, with load at every stage and a live failover test for the 2N UPS pair.
Electrical one-line
Solid lines are the A path, dashed the B path. Percentages are load against each unit's rating; in 2N each UPS carries half the IT load.
Redundancy checks
Recomputed on every telemetry update.
Cooling units
Vertiv Liebert DSE, N+1. Low return-to-supply ΔT points to bypass airflow.
Environmental audit
Every rack inlet sensor checked against ASHRAE TC 9.9 Class A1: recommended 18–27 °C dry bulb, dew point −9 to 15 °C, relative humidity 60% or lower.
Inlet conditions against the envelope
Each dot is one sensor (top, middle, bottom of every rack). Inner box: recommended. Outer box: A1 allowable.
Findings
Ranked by severity. Each one maps to a work order in production.
Allocation & billing
Contracted power against measured draw for every tenant, and every gap between what the room delivers and what HubSpot invoices.
Tenant allocation
Utilization is 24 h peak against contract. Tenants marked example are demo data.
Revenue leakage
Delivered in the room, missing from the invoice.
Cost analysis
Monthly cost to run the room, split by where the energy goes and who it serves. Rates are editable and recalculate everything.
Tariff and pricing
Modeled values. Replace them with your retail electric contract, the Oncor rate schedule and your price book.
Where the money goes
Projected month.
Cost to serve by tenant
IT energy times live PUE, plus each tenant's share of demand charges.
Savings
Energy measures ranked by annual value, sized from this room's own telemetry. Try a setpoint change before you make it.
What-if: supply air setpoint
Moves every Liebert DSE setpoint in the model. Watch the hottest inlet and the audit score.
Measures
4CP: ERCOT sets transmission charges from your load during the four 15-minute system peaks of June–September. Curtailing on alert days cuts next year's charge.